The TAR-463L is an advanced Automatic Recloser RCCB engineered to maximize power continuity without compromising electrical safety. By automatically restoring power supply after temporary earth leakage faults, this intelligent device minimizes downtime in residential, commercial, and light industrial installations. The integrated reclosing mechanism performs up to 6 automatic reconnection attempts with progressive delay intervals, ensuring optimal balance between safety and service reliability.
The TAR-463L Automatic Recloser RCCB represents a significant advancement in electrical protection technology, combining traditional earth leakage protection with intelligent automatic reclosing capabilities. This innovative device addresses one of the most common challenges in electrical installations: nuisance tripping caused by temporary earth leakage faults.
Unlike conventional RCCBs that require manual intervention after every trip event, the TAR-463L automatically attempts to restore power supply through a sophisticated 6-stage reclosing sequence. The progressive delay intervals (10s, 20s, 30s, 60s, 120s, and 600s) allow temporary faults to clear while preventing immediate re-energization that could pose safety risks.
The device integrates seamlessly into modern electrical distribution systems, offering auxiliary contacts for remote monitoring and control system integration. Its robust electromechanical design ensures reliable operation across a wide temperature range, making it suitable for both indoor and challenging outdoor applications.
With SIRIM approval and full compliance with IEC 61008-1 standards, the TAR-463L delivers peace of mind for installers and end-users alike, ensuring both regulatory compliance and superior performance in critical power distribution applications.
Reclosing Mechanism Technology: The TAR-463L employs an advanced automatic reclosing (REC) mechanism that operates on 220/240V AC at 50Hz. The recloser activates within 0.4 to 1.0 seconds following an RCCB trip event, initiating the first reconnection attempt after a 10-second delay. If the fault persists and causes subsequent tripping, the system progressively extends the delay period through six stages, allowing increasing time for temporary faults to clear naturally.
RCCB Protection Characteristics: The integrated electromechanical RCCB provides Type AC earth leakage protection with a rated residual current of 300mA (0.3A). The device is designed with a non-trip threshold of 0.5 × I∆n, ensuring stability against minor leakage currents while maintaining sensitivity to genuine fault conditions. With a rated breaking capacity of 500A and rated limited short-circuit current capacity of 6kA, the TAR-463L offers comprehensive protection against both earth leakage and overcurrent conditions.
Control and Monitoring: The device features toggle-type control and includes auxiliary contacts (1 NO + 1 NC) rated for 250V / 2A, enabling integration with building management systems, remote monitoring equipment, or alarm circuits. The dry contact configuration ensures electrical isolation between the main circuit and control systems.
Lockout and Reset Logic: After six unsuccessful reclosing attempts, the TAR-463L enters a lockout state, requiring manual reset to restart operation. This intelligent safety feature prevents continuous reclosing in the presence of persistent faults, ensuring personnel safety and preventing equipment damage.
Environmental Durability: Designed for demanding applications, the TAR-463L operates reliably across temperatures from -35°C to +70°C and humidity levels up to 93%. The device is rated for 5,000 electrical cycles, ensuring long-term reliability in high-utilization installations.
| Recloser (REC) Mechanism Specifications | |
|---|---|
| Rated Voltage (Un) | 220 / 240V AC |
| Rated Frequency | 50Hz |
| Reclosing Attempts | 6 times |
| Reclosing Delay Sequence | 10s → 20s → 30s → 60s → 120s → 600s |
| REC Power Consumption | 30VA |
| Operating Time | 0.4s < t < 1.0s |
| Control Type | Toggle |
| Auxiliary Contact | 1 NO + 1 NC (Dry contact) |
| Auxiliary Contact Capacity | Max 250V / 2A |
| RCCB Electrical Specifications | |
|---|---|
| Model Number | TAR-463L |
| Rated Current (In) | 63A |
| Rated Residual Current (I∆n) | 300mA (0.3A) |
| Poles | 4P (3P + N) |
| Rated Breaking Capacity (Im) | 500A |
| Rated Residual Breaking Capacity (I∆m) | 500A |
| Rated Limited Short-Circuit Current (Inc) | 6kA |
| Rated Limited Residual Short-Circuit Current (I∆c) | 6kA |
| Non-Trip Current | 0.5 × I∆n |
| Trip Unit Technology | Electromechanical |
| Mechanical & Environmental Characteristics | |
|---|---|
| Mounting Type | DIN Rail |
| Electrical Durability | 5,000 cycles |
| Padlockable | Yes |
| Degree of Protection | IP20 |
| Operating Temperature | -35°C to +70°C |
| Relative Humidity | 0 – 93% |
| Physical Dimensions (4-Pole Version) | |
|---|---|
| Height | 82 mm |
| Width | 130 mm |
| Depth | 76 mm |
| Standards & Compliance | |
|---|---|
| Certification | SIRIM Approved |
| Compliance Standards | IEC 61008-1 |
TL-4100S
4-Pole Residual Current Circuit Breaker (RCCB) with 100A rated current, 300mA sensitivity, and 10kA ...
View Details
TM-4100S
4-pole Residual Current Circuit Breaker (RCCB) with 100A rated current, 100mA earth-leakage sensitiv...
View Details
TL-463
4-pole Residual Current Circuit Breaker with 63A rated current, 10kA breaking capacity, and 30mA ear...
View Details
TL-440
4-pole Residual Current Circuit Breaker with 40A rated current, 10kA breaking capacity, and 300mA ea...
View Details
TL-263
2-pole Residual Current Circuit Breaker with 63A rated current, 10kA breaking capacity, and 300mA ea...
View Details
TL-240
2-Pole Residual Current Circuit Breaker with 40A rated current, 10kA breaking capacity, and 300mA ea...
View Details