TL-463 Residual Current Circuit Breaker (RCCB) 4P 63A 30mA

TL-463
TL-463 Residual Current Circuit Breaker (RCCB) 4P 63A 30mA

The TBC TL-463 is a professional-grade 4-pole Residual Current Circuit Breaker (RCCB) engineered for three-phase electrical distribution systems. Featuring 63A rated current capacity, 10kA breaking capacity, and 30mA earth-leakage sensitivity, this device provides reliable protection against electric shock and fire hazards caused by earth leakage currents. With electromechanical trip technology and instantaneous response, the TL-463 ensures maximum safety for personnel and equipment in commercial and industrial installations.

Key Features

  • 4-pole configuration (3P + N) for three-phase systems
  • 63A rated current capacity for high-load applications
  • 10kA breaking capacity for robust fault protection
  • 30mA earth-leakage sensitivity for personnel safety
  • Type AC earth-leakage protection class
  • Instantaneous tripping with no time delay
  • Electromechanical trip unit technology for reliable operation
  • Built-in TEST button for periodic functional verification
  • DIN rail mounting for easy installation
  • Manual toggle operation with clear ON/OFF indication
  • Wide operating temperature range: -35°C to +70°C
  • High mechanical durability: 10,000 cycles
  • Compliant with IEC 60898-1 standards
  • TÜV, CE, and CB certified
  • Compact design: 70mm width for space-efficient installation

The TBC TL-463 Residual Current Circuit Breaker is specifically designed to protect three-phase electrical distribution systems from dangerous earth-leakage currents. This 4-pole RCCB continuously monitors the electrical circuit and automatically disconnects power when it detects a leakage current exceeding 30mA, preventing electric shock injuries and reducing fire risks.

Built with electromechanical trip technology, the TL-463 offers superior reliability and does not require external power to operate. The device features instantaneous tripping characteristics, responding in less than 0.2 seconds at rated sensitivity and less than 0.04 seconds at 5 times rated sensitivity, ensuring rapid protection when needed most.

Designed for professional electrical installations, this RCCB is ideal for commercial buildings, industrial facilities, and power distribution systems where three-phase power is utilized. The robust construction ensures long service life with 10,000 mechanical cycles and 4,000 electrical cycles, while the IP20 protection rating makes it suitable for standard indoor electrical enclosures.

Installation is straightforward with standard DIN rail mounting, and the compact 70mm width allows for efficient use of panel space. The integrated TEST button enables regular functional testing to verify proper operation, supporting preventive maintenance programs and ensuring continuous protection reliability.

Operating Principle: The TL-463 operates on the principle of differential current detection. An internal toroidal transformer continuously monitors the balance between phase and neutral currents. When an earth-leakage fault occurs, the imbalance exceeds the 30mA threshold, triggering the electromechanical trip mechanism to disconnect all poles simultaneously.

Trip Unit Technology: The electromechanical trip unit does not require auxiliary power, making it inherently fail-safe. The Type AC classification means the device responds to alternating sinusoidal residual currents, suitable for standard AC loads.

Breaking Capacity: With a 10kA breaking capacity at 415V AC, the TL-463 can safely interrupt high fault currents, providing comprehensive protection in demanding industrial environments.

Tripping Characteristics: At nominal sensitivity (30mA), the device trips in less than 0.2 seconds. At 5 times nominal sensitivity (150mA), tripping occurs in less than 0.04 seconds, ensuring rapid disconnection during serious fault conditions.

Environmental Performance: The wide operating temperature range of -35°C to +70°C and humidity tolerance up to 95% make the TL-463 suitable for diverse installation environments, including locations with temperature variations and moderate humidity.

Standards Compliance: Manufactured in accordance with IEC 60898-1 international standards and certified by TÜV, CE, and CB, ensuring compliance with global safety and performance requirements.

  • Three-phase distribution boards in commercial and industrial facilities
  • Main and sub-distribution panels in office buildings
  • Shopping centers and retail complexes electrical systems
  • Manufacturing plants and industrial production facilities
  • Warehouses and logistics centers power distribution
  • Hotels, hospitals, and institutional buildings
  • Educational facilities and campus electrical infrastructure
  • Data centers and telecommunications facilities
  • Agricultural and farming operations with three-phase equipment
  • Water treatment and pumping stations
  • HVAC systems and mechanical equipment protection
  • Workshop and maintenance facility electrical panels
  • Food processing and cold storage facilities
  • Renewable energy installations and power distribution systems
ParameterSpecification
Product TypeResidual Current Circuit Breaker (RCCB)
Model NumberTL-463
Product ApplicationDistribution
Control TypeToggle
Poles Description3P + N (4 Pole)
Rated Current (In)63 A
Rated Voltage (Un)415 V AC
Frequency50 Hz
Network TypeAC
Earth-Leakage Sensitivity (IΔn)30 mA
Earth-Leakage Protection ClassType AC
Earth-Leakage Protection Time DelayInstantaneous
Trip Unit TechnologyElectromechanical
Breaking Capacity10 kA
Tripping Time at 1 × IΔn< 0.2 s
Tripping Time at 5 × IΔn< 0.04 s
Mounting TypeDIN Rail
Mechanical Durability10,000 cycles
Electrical Durability4,000 cycles
OperationManual toggle with TEST button
Height90.4 mm
Width70 mm
Depth75.3 mm
Ambient Air Temperature-35°C to +70°C
Relative Humidity0 – 95%
Degree of ProtectionIP20
Standards ComplianceIEC 60898-1, TÜV, CE, CB